Recurring Blocked Drain Cleared in Fitzroy

Completed Job Summary

A blocked drain in Fitzroy was cleared during a drainage service. High-pressure water jetting restored flow before a CCTV camera inspection identified two broken or damaged sections, two cracked sections and one area of major root ingress within the accessible drainage system.

Service type

Blocked Drain

Location

Fitzroy, VIC

Date completed

24 August 2026

Technician name

Taylor

Technician role

Senior Plumber

Job ID

82172

This job record is derived from first-party technician notes and the Simpro job management.

Customer report

The customer reported a blocked drain in Fitzroy. The technician’s notes also noted that the drain had been blocked for approximately six months and had previously been cleared using a snake. The current attendance was therefore associated with another blockage affecting the same drainage system. Client-provided images were referenced during the quoting stage, prior to the completed drainage work and CCTV inspection.

Diagnosis & Technical Assessment

The drainage system was assessed after the blockage was cleared using high-pressure water jetting. A CCTV camera inspection was then completed across accessible sections and branches of the drain.

The camera inspection covered the line from the boundary shaft through to the furthest ORG. Inspection was also completed from the ORG back towards the toilet, providing visibility of the accessible drainage path from both directions.

The CCTV inspection identified multiple physical defects within the system. Two sections were identified as broken or damaged, two additional sections were identified as cracked, and one area of major root ingress was observed.

These findings established that the drain contained several defects despite being operational after the blockage was cleared. The technician recorded the damaged sections, cracking and root ingress as the significant conditions identified during the investigation.

The available job evidence does not attribute the blockage to one individual defect. The CCTV findings instead document several conditions present within the drainage system following restoration of flow.

All work was completed in accordance with the Victorian Building Authority (VBA) regulatory framework.

Solutions delivered

High-pressure water jetting was used to clear the existing blockage and restore drainage flow. Once the blockage had been removed, a CCTV camera investigation was completed to examine accessible sections and branches of the drain and identify conditions within the pipework.

The inspection identified two broken or damaged sections, two cracked sections and an area of major root ingress. Based on those findings, the technician recorded two potential forms of further remedial work: excavation and replacement of the affected sections, or relining of the existing drain where suitable.

Neither excavation nor relining formed part of this completed attendance. The work completed for this job consisted of clearing the blockage using high-pressure water jetting and inspecting the accessible drainage system with CCTV.

This approach restored current flow while also documenting the physical defects requiring consideration for subsequent remedial work.

Tools, Parts & Systems Used

  • High-pressure water jetting equipment
  • CCTV camera
  • Drainage system

Outcome & Results

The blockage was successfully cleared, and the drain was running clear at completion of the work. CCTV inspection confirmed that physical defects remained within the drainage system, including two broken or damaged sections, two cracked sections and one area of major root ingress.

The drain was operational following jetting. Further options recorded by the technician were excavation and replacement of affected sections or relining where suitable.

All work was carried out in accordance with relevant Australian Standards and safety requirements.

Repair vs Replacement

The CCTV findings identified several forms of pipe damage rather than a blockage alone. For this job, high-pressure jetting restored flow, while the camera inspection established the condition of the accessible pipework.

The technician recorded excavation and replacement of affected sections as one potential remedial approach and relining as another, where the existing drain is suitable. Selection between those approaches was not completed as part of this attendance. The completed job therefore separates the immediate blockage clearance from any subsequent work addressing the damaged sections, cracks and root ingress.